For the complete documentation index, see llms.txt. This page is also available as Markdown.

Xovis

UMA Vision integrates with the Xovis PC2SE people-counting sensor, giving you accurate real-time occupancy data — whether the sensor is mounted in the centre of a room or over a building entrance.

Integration overview

Xovis PC2SE sensors push people-count data to UMA Vision over MQTT. Once connected, occupancy appears alongside all your other sensors on the floor map, device pages, insights, and analytics — with full support for auto-booking and auto-release.

Key features

  1. People counting:

    • Room occupancy — a single sensor in the centre of a room counts how many people are present, updating within a minute of someone entering or leaving

    • Floor and building occupancy — mount several sensors over the entrances to a floor or building, assign them all to the same UMA resource, and the counts are combined into a single total. Adding or removing a sensor takes effect immediately

    • Overnight reset — entrance-based running counts reset automatically each night, so small miscounts don't accumulate from one day to the next

  2. Booking automation:

    • Auto-book — enable automatic booking when occupancy is detected in a room

    • Auto-release — free the room automatically after the configured period with no one present. A momentary gap in the count does not release a room that is still in use

  3. Data visualisation:

    • Live and historical occupancy data from Xovis sensors are accessible on the main Insights dashboard and Device Insights pages

    • The floor map shows live occupancy for any resource linked to a Xovis sensor, identical to resources backed by other occupancy sensors

    • Floor-level and building-level occupancy totals include Xovis people counts

Getting started

Note: This integration requires access to the Xovis sensor's management interface (typically via the sensor's local IP address in a web browser). UMA will provide customer-specific MQTT connection details to connect the sensor to UMA Vision — contact your Customer Success Manager if you haven't received them.

Sensor types

The Xovis PC2SE can be deployed in two modes depending on where it is mounted:

Room centre (area counting) — the sensor is mounted in the centre of a room and counts the number of people present at any given moment. This is ideal for meeting rooms, collaboration spaces, and any enclosed area where you need a live headcount.

Entrance (in/out counting) — the sensor is mounted over a doorway or entrance and tracks people entering and leaving, maintaining a running total. Mount multiple sensors over all the entrances to a floor or building and assign them to the same UMA resource to get a combined occupancy figure. The running count resets overnight to prevent drift.

What you get in UMA Vision

Once connected, Xovis sensors work identically to other supported sensors in UMA Vision:

  • Real-time readings — live people count on device detail pages with online/offline status

  • Floor maps — occupancy status visible on your floor maps

  • Auto-booking and auto-release — occupancy sensors can automatically book and release rooms based on detected presence

  • Analytics and reporting — historical data flows through to sensor dashboards, Space Usage & Trends, and reports (Analytics Pro)

  • AI insights — use Explain with AI on sensor charts for plain-English summaries of trends and patterns (Enterprise)

Firewall rules

To check relevant firewall rules for the MQTT connection, see the Firewall rules page.

Last updated