For the complete documentation index, see llms.txt. This page is also available as Markdown.

Xovis configuration

Xovis Sensor Data Push Setup

The Xovis PC2SE sends data to UMA Vision via MQTT. You configure the data push in the sensor's own management interface.

Note: You will need access to the Xovis management interface for the sensor(s) you want to connect. This is typically accessed via the sensor's local IP address in a web browser.

Note: Unsure about UMA's MQTT server details? See the MQTT page.

Step 1 — Create an MQTT Connection

  1. In the Xovis management interface, go to Connections

  2. Click + Add connection and select MQTT

  3. Enter the Server URI, Port, and authentication credentials provided by UMA

  4. Enable SSL/TLS and leave Websocket off

  5. Under Advanced settings, set:

Setting
Value

Connection timeout (s)

10

QoS level

1 - At least once

Client id

Any unique identifier for this sensor

Topic

xovis

  1. Save the connection

Step 2 — Create a Logics Push Agent

  1. Go to Agents and click + Add new agent

  2. Select Logics Push as the agent type

  3. Set the Connection to the MQTT connection you just created

  4. On the Data tab, configure:

Setting
Value

Logics (Data filtering)

Select the logic you want in the payload

Format

JSON

Time format

Unix Time MS

Normalization

None

Full package info

Off

Full sensor info

On

Pretty format

Off

  1. On the Scheduling tab, configure:

Setting
Value

Scheduler type

Interval

Interval (package time)

1 minute

Resolution

1 minute

  1. Save the agent

  2. Ensure the agent shows as active (blue toggle enabled)

Warning: The Full sensor info toggle must be On — UMA Vision uses the sensor information in the payload to identify the device. Without it, data will arrive but cannot be matched to a resource.


Add the device to UMA

Once the sensor is pushing data to the MQTT broker, add it in UMA Vision:

  1. Navigate to Manage → Devices → Add Device

  2. Select Xovis as the device group

  3. Select Xovis PC2SE as the sensor type

  4. Enter the sensor's serial number as printed on the device

  5. Assign the sensor to a UMA resource — select the building, floor, and resource (room or zone)

  6. Click Save

Occupancy data will begin appearing within a minute of the sensor's next push.

Multiple sensors on one resource

To monitor a floor or building using entrance-based counting, assign all the entrance sensors to the same UMA resource (typically a zone representing the floor). Their counts are combined automatically — no additional configuration needed.

Tip: Optionally, you can allow any Xovis occupancy sensor to auto book or cancel a meeting booking by configuring the device settings.


Device page

Once connected, the Xovis device page shows:

  • Live people count — the current number of people detected

  • Online / offline status — the device shows as Online while it is sending data

  • Last seen — when the last data push was received, including while the space is empty and no one is moving

  • Serial number and registration date


Removing a sensor

To remove a Xovis sensor from UMA Vision:

  1. Navigate to Manage → Devices

  2. Locate the Xovis sensor and open its detail page

  3. Click Delete and confirm

Previously captured occupancy data is retained for historical reporting. To stop data arriving at the MQTT broker, also disable or delete the Logics Push Agent in the sensor's management interface.


Troubleshooting

Symptom
Check

Sensor shows as offline in UMA

Verify the MQTT connection is active in the Xovis management interface. Check that the Server URI, port, and credentials match what UMA provided

Data arriving but not matched to a resource

Ensure Full sensor info is toggled On in the agent's Data tab. Verify the serial number in UMA matches the sensor's actual serial number (case-insensitive)

People count seems incorrect for a floor

Check that all entrance sensors for the floor are assigned to the same UMA resource. The overnight reset clears accumulated drift each night

Sensor not appearing in UMA device list

Confirm the agent is active and the connection is established. Wait at least one minute for the first data push to arrive

Last updated

Was this helpful?